Clock Spring Pipeline External Corrosion Girth Weld

Clock Spring Pipeline External Corrosion Girth Weld

Middle East

Pipe Details:

48” high pressure major oil export pipeline
55 bar
40 C operating temperature


Defect Details:

Extensive external corrosion over a complete 10m joint length also affecting a girth weld location.


Repair Application:

Pipeline was grit blasted to a SA 2.5 surface preparation. Clock Spring was installed using a fully trained installation crew utilising the spool feeder technique. (A minimum of 6” clearance was available underneath the pipe).


Repair Time:

The complete repair application was completed in 3 work shifts.

Extent of external corrosion and girth weld defect.

Repair installation process utilising the spool feeder.

Continuation of repair application, bridging of the girth weld can be seen in the foreground.

Completed repair

HAVE A QUESTION OR NEED MORE INFORMATION? GET IN TOUCH.



Clock Spring has offices around the world with our global headquarters in Houston, TX, USA.

Have a question or need more information? Give us a call or fill in the form, and one of our representatives will reach out to you soon.

North America (USA)
621 Lockhaven Drive
Houston, TX 77073
P: +1-281-590-8491
F: +1-281-590-9528
Eastern Europe
M. Konopnickiej Street
No 2a
Bydgoszcz, Poland
85-124
P: +48 601 707 946
England
4A The Causeway
Godmanchester, Cambridgeshire
England PE29 2HA, UK
P: +44-1480-414-703
F: +44-1480-414-705
Middle East
Addax Tower Level 44
Office No. 4409
Al Reem Island
Abu Dhabi, UAE
P: +971 2 447 4288
M: +971 5 66758217
Scotland
54 Victoria Road
Aberdeen, Scotland
AB11 6FJ
P: +44 7985 396313






Speak with an expert

Fields with * are required








Inquiry Reason:
Market Segment:
How Can We Help?*: