<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Clock Spring Company, LP</title>
	<atom:link href="http://www.clockspring.com/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.clockspring.com</link>
	<description>World Leader In Pipeline Repair Solutions</description>
	<lastBuildDate>Tue, 21 Feb 2012 20:44:31 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
<xhtml:meta xmlns:xhtml="http://www.w3.org/1999/xhtml" name="robots" content="noindex" />
		<item>
		<title>Clock Spring Specifications</title>
		<link>http://www.clockspring.com/clock-spring-specifications/</link>
		<comments>http://www.clockspring.com/clock-spring-specifications/#comments</comments>
		<pubDate>Tue, 21 Feb 2012 20:41:27 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Clock Spring]]></category>
		<category><![CDATA[Technical]]></category>

		<guid isPermaLink="false">http://www.clockspring.com/?p=1702</guid>
		<description><![CDATA[Clock Spring specifications show its design to repair/reinforce damaged or corroded sections of pipe with up to 80% wall loss.  Standard Clock Spring contains e-glass continuous strand fibre all aligned in hoop direction and held within a polyester resin matrix. 20,000 hour tests completed (2.3 years duration) which are more representative of long term behaviour than the 1000 hour (42 days tests) required by ISO and ASME.  In-service monitoring of repairs, subsequent removal and testing for durations up to 7 years completed and reported.20 ksi (138 MPa) long-term allowable stress derived for 50 year life.]]></description>
			<content:encoded><![CDATA[<h1> Clock Spring Specifications</h1>
<p>Clock Spring specifications show its design to repair/reinforce damaged or corroded sections of pipe with up to 80% wall loss.</p>
<div class="one_half ">
<h2><strong><span style="text-decoration: underline;">Sleeve Specification</span></strong><strong>: </strong></h2>
<ul>
<li><strong>Number of wraps:  </strong>8 layers full cured laminate structure.  Each layer 0.06” thick.</li>
<li><strong>Nominal thickness:</strong>  0.500 inches (13mm) when installed.</li>
<li><strong>Service temperature:</strong>  -29°C to +77°C.</li>
<li><strong>Material:</strong>  E-glass continuous strand fibre all aligned in hoop direction and held within a polyester resin matrix.</li>
<li><strong>Width:</strong>  11.5” <sup>+</sup>/<sub>-</sub> 0.5” (292mm <sup>+</sup>/<sub>-</sub> 13mm).</li>
<li><strong>Service life:</strong>  &gt;50 years.</li>
</ul>
<h2></h2>
<h2><strong><span style="text-decoration: underline;">Adhesive Specification</span></strong><strong>:</strong></h2>
<ul>
<li><strong>Lap shear strength:</strong>  1200 psi (8.27 MPa).</li>
<li><strong>Shelf life:</strong>  12 months from date of manufacture.</li>
</ul>
<h2></h2>
<h2><strong><span style="text-decoration: underline;">Filler Specification:</span></strong></h2>
<ul>
<li><strong>Compressive strength:</strong>  &gt;8000 psi (55 MPa).</li>
<li><strong>Shelf life:</strong>  12 months from date of manufacture.</li>
</ul>
</div>
<div class="one_half last ">
<p><a href='http://www.clockspring.com/clock-spring-specifications/specifications-clock-spring-265-001/' title='specifications-clock spring-265-001'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/specifications-clock-spring-265-001-150x150.png" class="attachment-thumbnail" alt="Cut-away of Clock Spring" title="specifications-clock spring-265-001" /></a><br />
<a href='http://www.clockspring.com/clock-spring-specifications/specifications-clock-spring-265-002/' title='specifications-clock spring-265-002'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/specifications-clock-spring-265-002-150x150.jpg" class="attachment-thumbnail" alt="clock spring adhesive" title="specifications-clock spring-265-002" /></a><br />
<a href='http://www.clockspring.com/clock-spring-specifications/specifications-clock-spring-265-003/' title='specifications-clock spring-265-003'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/specifications-clock-spring-265-003-150x150.jpg" class="attachment-thumbnail" alt="Clock Spring filler" title="specifications-clock spring-265-003" /></a></p>
<p>&nbsp;</p>
</div>
<h2>Mechanical Values</h2>
<p><strong>Note:  All mechanical properties are measured on specimens that have been subject to an accelerated ageing process (in line with standard aerospace procedures) and saturated with water at elevated temperatures. </strong></p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="177"></td>
<td valign="top" width="168">
<p align="center"><strong>Circumferential</strong></p>
<p align="center"><strong> </strong></p>
</td>
<td valign="top" width="151">
<p align="center"><strong>Axial</strong></p>
</td>
</tr>
<tr>
<td valign="top" width="177"><em>Tensile modulus </em><em> </em></td>
<td valign="top" width="168">35.5 GPa (5 x 10<sup>6</sup> psi)</td>
<td valign="top" width="151">9.7 GPa (1.4 x 10<sup>6 </sup>psi)</td>
</tr>
<tr>
<td valign="top" width="177"><em>Tensile strain to failure </em><em> </em></td>
<td valign="top" width="168">1.6%</td>
<td valign="top" width="151">0.4%</td>
</tr>
<tr>
<td valign="top" width="177"><em>Tensile strength </em><em> </em></td>
<td valign="top" width="168">469 MPa (68 ksi)</td>
<td valign="top" width="151">40 MPa (5.8 ksi)</td>
</tr>
<tr>
<td valign="top" width="177"><em>Thermal expansion coefficient </em><em> </em></td>
<td valign="top" width="168">6.02 x 10<sup>-6</sup></td>
<td valign="top" width="151">32.6 x 10<sup>-6</sup></td>
</tr>
<tr>
<td valign="top" width="177"><em>Poisson’s ratio </em><em> </em></td>
<td valign="top" width="168">0.31</td>
<td valign="top" width="151">0.07</td>
</tr>
</tbody>
</table>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="177"><em>Shear modulus</em><em> </em></td>
<td valign="top" width="319">0.86 GPa (125 ksi)</td>
</tr>
<tr>
<td valign="top" width="177"><em>Shore A hardness</em><em> </em></td>
<td valign="top" width="319">Minimum 40</td>
</tr>
<tr>
<td valign="top" width="177"><em>Glass transition </em><em> </em></td>
<td valign="top" width="319">104°C (220°F)</td>
</tr>
<tr>
<td valign="top" width="177"><em>Lap shear strength to steel </em><em> </em></td>
<td valign="top" width="319">10.3 MPa (1500 psi)</td>
</tr>
<tr>
<td valign="top" width="177"><em>Aged lap shear strength </em><em> </em></td>
<td valign="top" width="319">8.3 MPa (1200 psi)</td>
</tr>
<tr>
<td valign="top" width="177"><em>Pipe survival tests</em><em> </em></td>
<td valign="top" width="319">151 tests completed</td>
</tr>
<tr>
<td valign="top" width="177"><em>Performance testing </em></td>
<td valign="top" width="319">20,000 hour tests completed (2.3 years duration) which are more representative of long term behaviour than the 1000 hour (42 days tests) required by ISO and ASME.  In-service monitoring of repairs, subsequent removal and testing for durations up to 7 years completed and reported.20 ksi (138 MPa) long-term allowable stress derived for 50 year life.</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.clockspring.com/clock-spring-specifications/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Installation Tips &#8211; Offshore HP Riser Repair</title>
		<link>http://www.clockspring.com/offshore-hp-riser-repair/</link>
		<comments>http://www.clockspring.com/offshore-hp-riser-repair/#comments</comments>
		<pubDate>Tue, 21 Feb 2012 16:03:27 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Installation]]></category>
		<category><![CDATA[Offshore]]></category>
		<category><![CDATA[Riser]]></category>

		<guid isPermaLink="false">http://www.clockspring.com/?p=1681</guid>
		<description><![CDATA[The following report is a pictorial and text account of procedures and operational techniques employed for the export riser repairs. The report is not meant as a technical report but serves as a QA/QC document for the installation of the Clock Spring system.]]></description>
			<content:encoded><![CDATA[<h1 align="left">HP Riser Repair</h1>
<p align="left">The following report is a pictorial and text account of procedures and operational techniques employed for the export riser repairs. The report is not meant as a technical report but serves as a QA/QC document for the installation of the Clock Spring system.</p>
<p>A HP riser has experienced extensive corrosion with wall loss of 82%, which is centered around the splash zone area.</p>
<p>A series of UT and visual inspection was conducted on the riser by the operator. The result was up to 82% wall loss is experienced by the riser, especially at the splash zone area. The previous coating has failed allowing the seawater to interact with the riser’s metal surface, causing extensive corrosion.</p>
<p>&nbsp;</p>
<h2>Engineering Analysis at Clock Spring Reinforced Area</h2>
<h3><strong>B31 Assessment / Deepest Defect</strong></h3>
<ul>
<li><strong>Defect Depth          </strong>8.1mm</li>
<li><strong>Defect Length      </strong> ~250mm</li>
<li><strong>Wall Loss % </strong>           82%</li>
<li><strong>Pristine Yield Pressure of the Pipe       </strong>  343.36 Bar</li>
<li><strong>Failure Pressure of Reinforced Pipe      </strong>421.2  Bar</li>
<li><strong>Reinforced Failure to Pristine Yield Ratio     </strong>1.06</li>
<li><strong>Suitability of Clock Spring Repair </strong>      <span style="color: #008000;"><strong>√</strong></span></li>
</ul>
<p><span style="color: #000000;">Pipe Diameter:  DN 200 mm<br />
Nominal Thickness: 10.00 mm</span></p>
<h2><span style="color: #000000;">Site Installation</span></h2>
<p><span style="color: #000000;">The installation of the Clock Spring® was conducted within 2 days in approximately 8 hours.</span></p>
<h2><span style="color: #000000;">Installation Photos</span></h2>
<h2><span style="color: #000000;"><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-001/' title='Riser Repair-Splash Zone-270-001'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-001-150x150.jpg" class="attachment-thumbnail" alt="Riser Repair Splash Zone" title="Riser Repair-Splash Zone-270-001" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-002/' title='Riser Repair-Splash Zone-270-002'><img width="150" height="138" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-002-150x138.jpg" class="attachment-thumbnail" alt="Splash Zone Corrosion" title="Riser Repair-Splash Zone-270-002" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-003/' title='Riser Repair-Splash Zone-270-003'><img width="150" height="139" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-003.jpg" class="attachment-thumbnail" alt="Splash Zone Corrosion" title="Riser Repair-Splash Zone-270-003" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-004/' title='Riser Repair-Splash Zone-270-004'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-004-150x150.jpg" class="attachment-thumbnail" alt="Pipe cleaned for repair" title="Riser Repair-Splash Zone-270-004" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-005/' title='Riser Repair-Splash Zone-270-005'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-005-150x150.jpg" class="attachment-thumbnail" alt="Pipe repair preparation" title="Riser Repair-Splash Zone-270-005" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-006/' title='Riser Repair-Splash Zone-270-006'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-006-150x150.jpg" class="attachment-thumbnail" alt="Pipe after sandblasting" title="Riser Repair-Splash Zone-270-006" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-007/' title='Riser Repair-Splash Zone-270-007'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-007-150x150.jpg" class="attachment-thumbnail" alt="HP Riser Repair" title="Riser Repair-Splash Zone-270-007" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-008/' title='Riser Repair-Splash Zone-270-008'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-008-150x150.jpg" class="attachment-thumbnail" alt="Filler application for pipe repair" title="Riser Repair-Splash Zone-270-008" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-009/' title='Riser Repair-Splash Zone-270-009'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-009-150x150.jpg" class="attachment-thumbnail" alt="Offshore adhesive Clock Spring" title="Riser Repair-Splash Zone-270-009" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-010/' title='Riser Repair-Splash Zone-270-010'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-010-150x150.jpg" class="attachment-thumbnail" alt="Clock Spring riser repair" title="Riser Repair-Splash Zone-270-010" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-011/' title='Riser Repair-Splash Zone-270-011'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-011-150x150.jpg" class="attachment-thumbnail" alt="clock spring applied offshore" title="Riser Repair-Splash Zone-270-011" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-012/' title='Riser Repair-Splash Zone-270-012'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-012-150x150.jpg" class="attachment-thumbnail" alt="Sealing edges of Clock Spring" title="Riser Repair-Splash Zone-270-012" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-013/' title='Riser Repair-Splash Zone-270-013'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-013-150x150.jpg" class="attachment-thumbnail" alt="Clock Spring offshore installation" title="Riser Repair-Splash Zone-270-013" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-014/' title='Riser Repair-Splash Zone-270-014'><img width="150" height="143" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-014-150x143.jpg" class="attachment-thumbnail" alt="Cinching a Clock Spring" title="Riser Repair-Splash Zone-270-014" /></a><br />
<a href='http://www.clockspring.com/offshore-hp-riser-repair/riser-repair-splash-zone-270-015/' title='Riser Repair-Splash Zone-270-015'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Splash-Zone-270-015-150x150.jpg" class="attachment-thumbnail" alt="completed clock spring installation offshore" title="Riser Repair-Splash Zone-270-015" /></a></p>
<p></span></h2>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.clockspring.com/offshore-hp-riser-repair/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Field Report- Tight Clearance &#8211; Hydrocarbon Line Corrosion &#8211; Offshore</title>
		<link>http://www.clockspring.com/field-report-tight-clearance-hydrocarbon-line-corrosion-offshore/</link>
		<comments>http://www.clockspring.com/field-report-tight-clearance-hydrocarbon-line-corrosion-offshore/#comments</comments>
		<pubDate>Wed, 15 Feb 2012 22:54:34 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Clock Spring]]></category>
		<category><![CDATA[External Corrosion]]></category>
		<category><![CDATA[Field Reports]]></category>
		<category><![CDATA[Offshore]]></category>

		<guid isPermaLink="false">http://www.clockspring.com/?p=1659</guid>
		<description><![CDATA[The defect is external corrosion with wall loss of 40%.  Tees are located both before and after the defect.   A 3” pipe hangs above the repair section with a tight clearance of only 3 inches.]]></description>
			<content:encoded><![CDATA[<h1>Offshore Repair Tight Clearance</h1>
<div class="one_half ">
<h2>Location:</h2>
<ul>
<li>West Malaysia</li>
<li>Offshore</li>
</ul>
<h2>Pipe Details:</h2>
<ul>
<li>8” diameter operating at 10 bars containing hydrocarbon at ambient temperature.</li>
</ul>
<h2>Defect Details:</h2>
<ul>
<li>The defect is external corrosion with <strong>wall loss of 40%.</strong></li>
<li><strong>Tees</strong> are located both <strong>before and after</strong> the defect.</li>
<li>A 3” pipe hangs above the repair section with a <strong>tight clearance of only 3 inches</strong>.</li>
</ul>
<h2>Repair Application:</h2>
<ul>
<li>Clock Spring reinforcement sleeve is used and applied using the<strong> <a title="Installation Guides" href="http://www.clockspring.com/resources/installation-guides/">hand spool technique </a></strong>to meet the tight clearance restriction.</li>
</ul>
<h2>Repair Time:</h2>
<ul>
<li>The repair took<strong> 45 minutes to complete</strong>.</li>
</ul>
</div>
<div class="one_half last ">
<p><a href='http://www.clockspring.com/field-report-tight-clearance-hydrocarbon-line-corrosion-offshore/tight-clearance-offshore-west-malaysia-268-001/' title='Tight Clearance - Offshore - West Malaysia-268-001'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Tight-Clearance-Offshore-West-Malaysia-268-001-150x150.jpg" class="attachment-thumbnail" alt="8&quot; pipe with corrosion, close proximity to 3&quot; line" title="Tight Clearance - Offshore - West Malaysia-268-001" /></a><br />
<a href='http://www.clockspring.com/field-report-tight-clearance-hydrocarbon-line-corrosion-offshore/tight-clearance-offshore-west-malaysia-268-002/' title='Tight Clearance - Offshore - West Malaysia-268-002'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Tight-Clearance-Offshore-West-Malaysia-268-002-150x150.jpg" class="attachment-thumbnail" alt="Filler and adhesive applied" title="Tight Clearance - Offshore - West Malaysia-268-002" /></a><br />
<a href='http://www.clockspring.com/field-report-tight-clearance-hydrocarbon-line-corrosion-offshore/tight-clearance-offshore-west-malaysia-268-003/' title='Tight Clearance - Offshore - West Malaysia-268-003'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Tight-Clearance-Offshore-West-Malaysia-268-003-150x150.jpg" class="attachment-thumbnail" alt="Coil applied and held in position whilst curing" title="Tight Clearance - Offshore - West Malaysia-268-003" /></a><br />
<a href='http://www.clockspring.com/field-report-tight-clearance-hydrocarbon-line-corrosion-offshore/tight-clearance-offshore-west-malaysia-268-004/' title='Tight Clearance - Offshore - West Malaysia-268-004'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Tight-Clearance-Offshore-West-Malaysia-268-004-150x150.jpg" class="attachment-thumbnail" alt="Completed repair" title="Tight Clearance - Offshore - West Malaysia-268-004" /></a></p>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.clockspring.com/field-report-tight-clearance-hydrocarbon-line-corrosion-offshore/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Field Report &#8211; Offshore Riser Repair</title>
		<link>http://www.clockspring.com/field-report-offshore-riser-repair/</link>
		<comments>http://www.clockspring.com/field-report-offshore-riser-repair/#comments</comments>
		<pubDate>Wed, 15 Feb 2012 22:36:38 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Clock Spring]]></category>
		<category><![CDATA[Field Reports]]></category>
		<category><![CDATA[Offshore]]></category>
		<category><![CDATA[Riser]]></category>

		<guid isPermaLink="false">http://www.clockspring.com/?p=1644</guid>
		<description><![CDATA[Extensive external corrosion up to 82% wall loss covering circumferential area, especially at the mean sea level (splash zone). 
Offshore Riser Repair with Clock Spring reinforcement sleeve with marine type chemicals utilised.  These chemicals have been tested for sub-sea application and will cure even when submerged.  The total length of riser being repaired is 5.2 meters. Installation was completed within 9 hours, spanning 1 ½ days. The splash zone section of the riser was repaired within one hour as the crew only had a one hour window at low tide.]]></description>
			<content:encoded><![CDATA[<h1>Offshore Riser Repair</h1>
<div id="attachment_1647" class="wp-caption alignright" style="width: 238px"><a href="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Offshore-West-Malaysia-266-001.jpg"><img class="size-full wp-image-1647" title="Riser Repair-Offshore-West Malaysia-266-001" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Offshore-West-Malaysia-266-001.jpg" alt="" width="228" height="170" /></a>
<p class="wp-caption-text">Completed Repair (Center of Photo)</p>
</div>
<h2>Location:</h2>
<ul>
<li>West Malaysia</li>
<li><a title="Offshore" href="http://www.clockspring.com/slides/offshore/">Offshore Riser</a></li>
</ul>
<h2>Pipe Details:</h2>
<ul>
<li>8” diameter</li>
<li>40 Bar operating pressure</li>
<li>30°- 40°C ambient temperature</li>
</ul>
<h2>Defect Details:</h2>
<ul>
<li>Extensive <a title="External Corrosion" href="http://www.clockspring.com/repair-types/external-corrosion/">external corrosion</a> up to 82% wall loss covering circumferential area, especially at the mean sea level (splash zone).</li>
</ul>
<h2>Repair Application:</h2>
<ul>
<li><a title="Clock Spring®" href="http://www.clockspring.com/products/clock-spring/">Clock Spring </a>reinforcement sleeve with <a title="MSDS" href="http://www.clockspring.com/safety/msds/">marine type chemicals</a> utilised.  These chemicals have been tested for sub-sea application and will cure even when submerged.  The total length of riser being repaired is 5.2 meters.</li>
</ul>
<h2>Repair Time:</h2>
<ul>
<li>Installation was <strong>completed within 9 hours, spanning 1 ½ days</strong>.</li>
<li>The <strong>splash zone section of the riser was repaired within one hour</strong> as the crew only had a one hour window at low tide.</li>
</ul>
<p><a href='http://www.clockspring.com/field-report-offshore-riser-repair/riser-repair-offshore-west-malaysia-266-001/' title='Riser Repair-Offshore-West Malaysia-266-001'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Offshore-West-Malaysia-266-001-150x150.jpg" class="attachment-thumbnail" alt="Completed Repair (Center of Photo)" title="Riser Repair-Offshore-West Malaysia-266-001" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-riser-repair/riser-repair-offshore-west-malaysia-266-002/' title='Riser Repair-Offshore-West Malaysia-266-002'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Offshore-West-Malaysia-266-002-150x150.jpg" class="attachment-thumbnail" alt="Coil installation in progress" title="Riser Repair-Offshore-West Malaysia-266-002" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-riser-repair/riser-repair-offshore-west-malaysia-266-003/' title='Riser Repair-Offshore-West Malaysia-266-003'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Offshore-West-Malaysia-266-003-150x150.jpg" class="attachment-thumbnail" alt="Installation included girth welds. Repairs submerged due to tide." title="Riser Repair-Offshore-West Malaysia-266-003" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-riser-repair/riser-repair-offshore-west-malaysia-266-004/' title='Riser Repair-Offshore-West Malaysia-266-004'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Offshore-West-Malaysia-266-004-150x150.jpg" class="attachment-thumbnail" alt="5 metre total section repair" title="Riser Repair-Offshore-West Malaysia-266-004" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-riser-repair/riser-repair-offshore-west-malaysia-266-005/' title='Riser Repair-Offshore-West Malaysia-266-005'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Offshore-West-Malaysia-266-005-150x150.jpg" class="attachment-thumbnail" alt="Condition of the riser before surface preparation" title="Riser Repair-Offshore-West Malaysia-266-005" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-riser-repair/riser-repair-offshore-west-malaysia-266-006/' title='Riser Repair-Offshore-West Malaysia-266-006'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Offshore-West-Malaysia-266-006-150x150.jpg" class="attachment-thumbnail" alt="Condition of the most affected area of the riser by corrosion" title="Riser Repair-Offshore-West Malaysia-266-006" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-riser-repair/riser-repair-offshore-west-malaysia-266-007/' title='Riser Repair-Offshore-West Malaysia-266-007'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Offshore-West-Malaysia-266-007-150x150.jpg" class="attachment-thumbnail" alt="The corroded area removed" title="Riser Repair-Offshore-West Malaysia-266-007" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-riser-repair/riser-repair-offshore-west-malaysia-266-008/' title='Riser Repair-Offshore-West Malaysia-266-008'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Offshore-West-Malaysia-266-008-150x150.jpg" class="attachment-thumbnail" alt="Surface preparation in progress" title="Riser Repair-Offshore-West Malaysia-266-008" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-riser-repair/riser-repair-offshore-west-malaysia-266-009/' title='Riser Repair-Offshore-West Malaysia-266-009'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Offshore-West-Malaysia-266-009-150x150.jpg" class="attachment-thumbnail" alt="The pipe condition after blasting" title="Riser Repair-Offshore-West Malaysia-266-009" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-riser-repair/riser-repair-offshore-west-malaysia-266-010/' title='Riser Repair-Offshore-West Malaysia-266-010'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Riser-Repair-Offshore-West-Malaysia-266-010-150x150.jpg" class="attachment-thumbnail" alt="The pipe condition after blasting" title="Riser Repair-Offshore-West Malaysia-266-010" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.clockspring.com/field-report-offshore-riser-repair/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Field Report &#8211; Offshore Tight Clearance Repair</title>
		<link>http://www.clockspring.com/field-report-offshore-tight-clearance-repair/</link>
		<comments>http://www.clockspring.com/field-report-offshore-tight-clearance-repair/#comments</comments>
		<pubDate>Wed, 15 Feb 2012 19:51:08 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Clock Spring]]></category>
		<category><![CDATA[Field Reports]]></category>
		<category><![CDATA[Offshore]]></category>

		<guid isPermaLink="false">http://www.clockspring.com/?p=1634</guid>
		<description><![CDATA[Field report from West Malaysia of Clock Spring corrosion repair completed in area of tight clearance.  The piping located at cellar deck with wall loss of 50% at 6 o’clock position.  The length of the defect is approximately 200mm long.  The repair section of the piping is located in close proximity to another 12” pipe.

Clock Spring reinforcement sleeve was used as a repair method using the hand spool technique.]]></description>
			<content:encoded><![CDATA[<h1>Offshore Tight Clearance Repair</h1>
<div class="one_half ">
<h2>Location:</h2>
<ul>
<li>West Malaysia</li>
<li><a title="Offshore" href="http://www.clockspring.com/capabilities/application-types/offshore-corrosion-repair/">Offshore</a> (Top Side)</li>
</ul>
<h2>Pipe Details:</h2>
<ul>
<li>8” diameter operating at 10 bars containing<a title="Hydrocarbons" href="http://www.clockspring.com/capabilities/application-types/hydrocarbons/"> hydrocarbon</a> at ambient temperature.</li>
</ul>
<h2>Defect Details:</h2>
<ul>
<li>Piping located at cellar deck with<strong> wall loss of 50% at 6 o’clock position</strong>.</li>
<li>The length of the defect is approximately 200mm long.</li>
<li>Repair section of the piping is located in <strong>close proximity to another 12” pipe</strong>.</li>
</ul>
<h2>Repair Application:</h2>
<ul>
<li><a title="Clock Spring®" href="http://www.clockspring.com/products/clock-spring/">Clock Spring®</a>  reinforcement sleeve was used as a repair method using the <a title="Installation Guides" href="http://www.clockspring.com/resources/installation-guides/">hand spool technique</a>.</li>
<li>Clock Spring®  is able to be used even in areas with tight clearance restrictions.</li>
</ul>
<h2>Repair Time:</h2>
<ul>
<li>The repair took <strong>40 minutes to complete.</strong></li>
</ul>
</div>
<div class="one_half last ">
<p><a href='http://www.clockspring.com/field-report-offshore-tight-clearance-repair/tight-clearance-offshore-west-malaysia-267-001/' title='Tight Clearance - Offshore - West Malaysia-267-001'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Tight-Clearance-Offshore-West-Malaysia-267-001-150x150.jpg" class="attachment-thumbnail" alt="Extensive external corrosion" title="Tight Clearance - Offshore - West Malaysia-267-001" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-tight-clearance-repair/tight-clearance-offshore-west-malaysia-267-002/' title='Tight Clearance - Offshore - West Malaysia-267-002'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Tight-Clearance-Offshore-West-Malaysia-267-002-150x150.jpg" class="attachment-thumbnail" alt="Application of filler and starter pad" title="Tight Clearance - Offshore - West Malaysia-267-002" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-tight-clearance-repair/tight-clearance-offshore-west-malaysia-267-003/' title='Tight Clearance - Offshore - West Malaysia-267-003'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Tight-Clearance-Offshore-West-Malaysia-267-003-150x150.jpg" class="attachment-thumbnail" alt="Coil installation made using hand spool due to tight clearance" title="Tight Clearance - Offshore - West Malaysia-267-003" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-tight-clearance-repair/tight-clearance-offshore-west-malaysia-267-004/' title='Tight Clearance - Offshore - West Malaysia-267-004'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Tight-Clearance-Offshore-West-Malaysia-267-004-150x150.jpg" class="attachment-thumbnail" alt="Completed Clock Spring® installation" title="Tight Clearance - Offshore - West Malaysia-267-004" /></a></p>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.clockspring.com/field-report-offshore-tight-clearance-repair/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Field Report &#8211; Process Plant Pipe Corrosion Repair</title>
		<link>http://www.clockspring.com/process-plant-pipe-corrosion-repair/</link>
		<comments>http://www.clockspring.com/process-plant-pipe-corrosion-repair/#comments</comments>
		<pubDate>Wed, 15 Feb 2012 17:26:43 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Field Reports]]></category>
		<category><![CDATA[Pipe Support]]></category>
		<category><![CDATA[Plant and Refinery]]></category>

		<guid isPermaLink="false">http://www.clockspring.com/?p=1622</guid>
		<description><![CDATA[Field report featuring major rehabilitation project (over 654 locations) in process plant to correct pipe corrosion at support contact points. Project utilized repairs at over 654 pipe support locations. Each repair installed <15 minutes.]]></description>
			<content:encoded><![CDATA[<h1>Process Plant Corrosion Repair</h1>
<div class="one_half ">
<h2>Location:</h2>
<ul>
<li>Malaysia</li>
<li>Process plant</li>
</ul>
<h2>Pipe Details:</h2>
<ul>
<li>2” – 18” diameter</li>
<li>Process pipelines</li>
</ul>
<h2>Repair Application:</h2>
<ul>
<li><strong>Major rehabilitation program</strong> of <strong><a title="Pipe Support" href="http://www.clockspring.com/products/pipe-support/">over 654 pipe support</a></strong> locations.</li>
<li>Corrosion issues due to <strong>water entrapment and galvanic conditions</strong> as well as erosion due to <strong>pipeline movement</strong>.</li>
<li>Pipe was lifted at each support location and the pipe surface manually cleaned using power brush techniques.</li>
<li><strong>Pipe supports installed within 15 minutes</strong> and once cured (within 1 hour) the pipe was lowered back onto the support.</li>
</ul>
</div>
<div class="one_half last ">
<p><a href='http://www.clockspring.com/process-plant-pipe-corrosion-repair/pipe-support-corrosion-malaysia-264-001/' title='Pipe Support-Corrosion-Malaysia-264-001'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Pipe-Support-Corrosion-Malaysia-264-001-150x150.jpg" class="attachment-thumbnail" alt="Pipe Support-Corrosion-Malaysia-264-001" title="Pipe Support-Corrosion-Malaysia-264-001" /></a><br />
<a href='http://www.clockspring.com/process-plant-pipe-corrosion-repair/pipe-support-corrosion-malaysia-264-002/' title='Pipe Support-Corrosion-Malaysia-264-002'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Pipe-Support-Corrosion-Malaysia-264-002-150x150.jpg" class="attachment-thumbnail" alt="Pipe Support-Corrosion-Malaysia-264-002" title="Pipe Support-Corrosion-Malaysia-264-002" /></a><br />
<a href='http://www.clockspring.com/process-plant-pipe-corrosion-repair/pipe-support-corrosion-malaysia-264-003/' title='Pipe Support-Corrosion-Malaysia-264-003'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Pipe-Support-Corrosion-Malaysia-264-003-150x150.jpg" class="attachment-thumbnail" alt="Pipe Support-Corrosion-Malaysia-264-003" title="Pipe Support-Corrosion-Malaysia-264-003" /></a></p>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.clockspring.com/process-plant-pipe-corrosion-repair/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Field Report &#8211; Discharge Pump Leak Repair &#8211; Contour</title>
		<link>http://www.clockspring.com/field-report-discharge-pump-leak-repair-contour/</link>
		<comments>http://www.clockspring.com/field-report-discharge-pump-leak-repair-contour/#comments</comments>
		<pubDate>Wed, 15 Feb 2012 17:00:53 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Contour]]></category>
		<category><![CDATA[Field Reports]]></category>
		<category><![CDATA[Leak]]></category>

		<guid isPermaLink="false">http://www.clockspring.com/?p=1612</guid>
		<description><![CDATA[Field Report of offshore leak repair in West Africa. 6” inlet pipe on discharge pump with small pin hole leaks close to “tee” girth weld. Repair required temporary shut down of the pump whilst area manually cleaned and pin hole sealed with leak sealing compound. Clock Spring Contour application over the complete complex tee geometry and all affected girth welds.  Repair designed in accordance to ISO TS24817. ]]></description>
			<content:encoded><![CDATA[<h1>Discharge Pump Repair with Contour</h1>
<div class="one_half ">
<h2>Location:</h2>
<ul>
<li>West Africa</li>
<li>Offshore</li>
</ul>
<h2>Component Details:</h2>
<ul>
<li>6” inlet pipe on discharge pump</li>
<li>5 bar pressure</li>
</ul>
<h2>Repair Application:</h2>
<ul>
<li>Small pin hole leaks close to “tee” girth weld.</li>
<li>Temporary shut down of the pump whilst area manually cleaned and pin hole sealed with leak sealing compound.</li>
<li>Clock Spring Contour application over the complete complex tee geometry and all affected girth welds.  Repair designed in accordance to ISO TS24817.</li>
</ul>
</div>
<div class="one_half last ">
<p><a href='http://www.clockspring.com/field-report-discharge-pump-leak-repair-contour/leak-offshore-contour-west-africa-263-001/' title='Leak Offshore-Contour-West Africa-263-001'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Leak-Offshore-Contour-West-Africa-263-001-150x150.jpg" class="attachment-thumbnail" alt="Identified pin hole leaks" title="Leak Offshore-Contour-West Africa-263-001" /></a><br />
<a href='http://www.clockspring.com/field-report-discharge-pump-leak-repair-contour/leak-offshore-contour-west-africa-263-002/' title='Leak Offshore-Contour-West Africa-263-002'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Leak-Offshore-Contour-West-Africa-263-002-150x150.jpg" class="attachment-thumbnail" alt="Component cleaned and leak sealing compound applied" title="Leak Offshore-Contour-West Africa-263-002" /></a><br />
<a href='http://www.clockspring.com/field-report-discharge-pump-leak-repair-contour/leak-offshore-contour-west-africa-263-003/' title='Leak Offshore-Contour-West Africa-263-003'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Leak-Offshore-Contour-West-Africa-263-003-150x150.jpg" class="attachment-thumbnail" alt="Finished repair application" title="Leak Offshore-Contour-West Africa-263-003" /></a></p>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.clockspring.com/field-report-discharge-pump-leak-repair-contour/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Field Report &#8211; High Temperature Pipeline Girth Weld Repair</title>
		<link>http://www.clockspring.com/field-report-high-temperature-pipeline-girth-weld-repair/</link>
		<comments>http://www.clockspring.com/field-report-high-temperature-pipeline-girth-weld-repair/#comments</comments>
		<pubDate>Wed, 15 Feb 2012 16:15:53 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Clock Spring]]></category>
		<category><![CDATA[Field Reports]]></category>
		<category><![CDATA[High Temperature]]></category>

		<guid isPermaLink="false">http://www.clockspring.com/?p=1600</guid>
		<description><![CDATA[30” main oil export line
70 bar operating pressure
+70°C operating temperature
Repair Application: 
Field report exploring repair of a girth weld repair on a high temperature oil export line in West Africa. Defects featured general external corrosion at girth welds due to poor application of field joint coatings. Standard girth weld bridging technique utilised with high temperature Clock Spring system, suitable for up to 120°C service temperature. ]]></description>
			<content:encoded><![CDATA[<h2>High Temperature Pipeline Girth Weld</h2>
<div class="one_half ">
<h2>Location:</h2>
<ul>
<li>West Africa</li>
<li>High temperature pipeline</li>
</ul>
<h2>Pipe Details:</h2>
<ul>
<li>30” main oil export line</li>
<li>70 bar operating pressure</li>
<li>+70°C operating temperature</li>
</ul>
<h2>Repair Application:</h2>
<ul>
<li>General external corrosion at girth welds due to poor application of field joint coatings.</li>
<li>Standard girth weld bridging technique utilised with high temperature Clock Spring system, suitable for up to 120°C service temperature.</li>
</ul>
</div>
<div class="one_half last ">
<a href='http://www.clockspring.com/field-report-high-temperature-pipeline-girth-weld-repair/girth-weld-pipeline-ht-west-africa-262-001/' title='Girth Weld-Pipeline-HT-West Africa-262-001'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Girth-Weld-Pipeline-HT-West-Africa-262-001-150x150.jpg" class="attachment-thumbnail" alt="Corrosion at girth weld" title="Girth Weld-Pipeline-HT-West Africa-262-001" /></a><br />
<a href='http://www.clockspring.com/field-report-high-temperature-pipeline-girth-weld-repair/girth-weld-pipeline-ht-west-africa-262-002/' title='Girth Weld-Pipeline-HT-West Africa-262-002'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Girth-Weld-Pipeline-HT-West-Africa-262-002-150x150.jpg" class="attachment-thumbnail" alt="Application of first bridging unit" title="Girth Weld-Pipeline-HT-West Africa-262-002" /></a><br />
<a href='http://www.clockspring.com/field-report-high-temperature-pipeline-girth-weld-repair/girth-weld-pipeline-ht-west-africa-262-003/' title='Girth Weld-Pipeline-HT-West Africa-262-003'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Girth-Weld-Pipeline-HT-West-Africa-262-003-150x150.jpg" class="attachment-thumbnail" alt="Second bridging unit installed" title="Girth Weld-Pipeline-HT-West Africa-262-003" /></a><br />
<a href='http://www.clockspring.com/field-report-high-temperature-pipeline-girth-weld-repair/girth-weld-pipeline-ht-west-africa-262-004/' title='Girth Weld-Pipeline-HT-West Africa-262-004'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Girth-Weld-Pipeline-HT-West-Africa-262-004-150x150.jpg" class="attachment-thumbnail" alt="Completed repair" title="Girth Weld-Pipeline-HT-West Africa-262-004" /></a></p>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.clockspring.com/field-report-high-temperature-pipeline-girth-weld-repair/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Field Report &#8211; New Pipeline Construction with Pipe Support Application</title>
		<link>http://www.clockspring.com/field-report-new-pipeline-construction-with-pipe-support-application/</link>
		<comments>http://www.clockspring.com/field-report-new-pipeline-construction-with-pipe-support-application/#comments</comments>
		<pubDate>Wed, 15 Feb 2012 15:46:45 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Field Reports]]></category>
		<category><![CDATA[Pipe Support]]></category>

		<guid isPermaLink="false">http://www.clockspring.com/?p=1582</guid>
		<description><![CDATA[Field report of pipe support installation in Luxembourg on new pipeline fitted during line construction to prevent all future problems associated with crevice, galvanic corrosion and erosion.  ]]></description>
			<content:encoded><![CDATA[<h1>New Pipeline Construction &#8211; Installation of Pipe Support Sleeves</h1>
<div class="one_half ">
<h2>Location:</h2>
<ul>
<li>Luxembourg</li>
</ul>
<h2>Pipe Details:</h2>
<ul>
<li>12” domestic <a title="Water Lines" href="http://www.clockspring.com/capabilities/application-types/water-lines/">water line</a></li>
</ul>
<h2>Repair Application:</h2>
<ul>
<li>Design guidelines requested protection of the pipe at each support location.</li>
<li><a title="Pipe Support" href="http://www.clockspring.com/products/pipe-support/">Pipe supports</a> fitted during the line construction to prevent all future problems associated with crevice, galvanic corrosion and erosion.</li>
<li>After installation corrosion coating was applied and the <a title="Pipe Support" href="http://www.clockspring.com/products/pipe-support/">pipe support</a> fabrication then completed.</li>
</ul>
</div>
<div class="one_half last ">
<p><a href='http://www.clockspring.com/field-report-new-pipeline-construction-with-pipe-support-application/new-pipeline-pipe-support-luxembourg-261-001/' title='New Pipeline-Pipe Support-Luxembourg-261-001'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/New-Pipeline-Pipe-Support-Luxembourg-261-001-150x150.png" class="attachment-thumbnail" alt="Pipe preparation" title="New Pipeline-Pipe Support-Luxembourg-261-001" /></a><br />
<a href='http://www.clockspring.com/field-report-new-pipeline-construction-with-pipe-support-application/new-pipeline-pipe-support-luxembourg-261-002/' title='New Pipeline-Pipe Support-Luxembourg-261-002'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/New-Pipeline-Pipe-Support-Luxembourg-261-002-150x150.png" class="attachment-thumbnail" alt="Pipe support installed" title="New Pipeline-Pipe Support-Luxembourg-261-002" /></a><br />
<a href='http://www.clockspring.com/field-report-new-pipeline-construction-with-pipe-support-application/new-pipeline-pipe-support-luxembourg-261-003/' title='New Pipeline-Pipe Support-Luxembourg-261-003'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/New-Pipeline-Pipe-Support-Luxembourg-261-003-150x150.png" class="attachment-thumbnail" alt="Pipeline coated and pipe support construction completed" title="New Pipeline-Pipe Support-Luxembourg-261-003" /></a></p>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.clockspring.com/field-report-new-pipeline-construction-with-pipe-support-application/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Field Report &#8211; Offshore Structural Repair with Snap Wrap</title>
		<link>http://www.clockspring.com/field-report-offshore-structural-repair-with-snap-wrap/</link>
		<comments>http://www.clockspring.com/field-report-offshore-structural-repair-with-snap-wrap/#comments</comments>
		<pubDate>Wed, 15 Feb 2012 15:19:30 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Field Reports]]></category>
		<category><![CDATA[Offshore]]></category>
		<category><![CDATA[Snap Wrap]]></category>

		<guid isPermaLink="false">http://www.clockspring.com/?p=1570</guid>
		<description><![CDATA[Field report of offshore structural repair in Middle East featuring 8 metre repair length with severe external corrosion (up to 80%) metal loss on 14" heavy wall structural cross member designed to hold riser support clamps. Solution features engineered heavy wall composite sleeve, extensive filler application and molding to rebuild pipe surface, more...]]></description>
			<content:encoded><![CDATA[<h1>Offshore Structural Repair using Snap Wrap</h1>
<div class="one_half ">
<h2>Location:</h2>
<ul>
<li>Middle East</li>
<li>Offshore</li>
</ul>
<h2>Pipe Details:</h2>
<ul>
<li>14” heavy wall structural cross member.</li>
<li>8 metre repair length.</li>
</ul>
<h2>Repair Application:</h2>
<ul>
<li>Severe <a title="External Corrosion" href="http://www.clockspring.com/repair-types/external-corrosion/">external corrosion</a> (up to 80%) metal loss on structural member designed to hold riser support clamps.</li>
<li>Engineered heavy wall <a title="Snap Wrap" href="http://www.clockspring.com/products/snap-wrap/">composite sleeve</a>, manufactured in 600mm widths using bi-axial glass architecture.</li>
<li>Extensive filler application and molding to rebuild pipe surface to original outer diameter and sleeves installed and cut to length in a brick wall fashion.</li>
<li>Once completed riser holding clamps reinstated over the offshore structural repair area.</li>
</ul>
<div class="mceTemp"></div>
</div>
<div class="one_half last ">
<p><a href='http://www.clockspring.com/field-report-offshore-structural-repair-with-snap-wrap/structural-offshore-snap-wrap-260-004/' title='Structural - Offshore - Snap Wrap-260-004'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Structural-Offshore-Snap-Wrap-260-004-150x150.jpg" class="attachment-thumbnail" alt="Riser holding clamps reinstated onto repair and riser." title="Structural - Offshore - Snap Wrap-260-004" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-structural-repair-with-snap-wrap/structural-offshore-snap-wrap-260-001/' title='Structural - Offshore - Snap Wrap-260-001'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Structural-Offshore-Snap-Wrap-260-001-150x150.jpg" class="attachment-thumbnail" alt="Pipe cleaned and showing severe external corrosion" title="Structural - Offshore - Snap Wrap-260-001" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-structural-repair-with-snap-wrap/structural-offshore-snap-wrap-260-002/' title='Structural - Offshore - Snap Wrap-260-002'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Structural-Offshore-Snap-Wrap-260-002-150x150.jpg" class="attachment-thumbnail" alt="Repair sleeves installed" title="Structural - Offshore - Snap Wrap-260-002" /></a><br />
<a href='http://www.clockspring.com/field-report-offshore-structural-repair-with-snap-wrap/structural-offshore-snap-wrap-260-003/' title='Structural - Offshore - Snap Wrap-260-003'><img width="150" height="150" src="http://www.clockspring.com/wp-content/uploads/2012/02/Structural-Offshore-Snap-Wrap-260-003-150x150.jpg" class="attachment-thumbnail" alt="Sealing of completed repair area prior to corrosion coating application" title="Structural - Offshore - Snap Wrap-260-003" /></a></p>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.clockspring.com/field-report-offshore-structural-repair-with-snap-wrap/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>